Pandora K2P mining
Publish: 2021-05-27 03:59:03
1. K2P, K3 and the current k3c have all been tested. My family has an attic, and the router, K2P and K3 placed downstairs can detect the signal in the corner of the attic, but the k3c is the best signal at present. It seems that the 6dp antenna is still a good signal guarantee. If the pursuit of signal effect, it must be k3c is the best, especially when 2.4G and 5g are used at the same time, k3c is the best, K3 is not practical. In my environment, K2P needs to open 5g to have good practical effect, k3c is completely competent. It's worth recommending!
2. 128+16
3. The minimum average thickness of UL style 18awg is 30mils, that is, 0.76mm.
18awg stranded conctor outer diameter is 1.18mm.
1.18 + 0.76 * 2 = 2.7mm, plus the thickness of 0.2 ~ 0.3mm, the finished proct is about 3.0mm
18awg stranded conctor outer diameter is 1.18mm.
1.18 + 0.76 * 2 = 2.7mm, plus the thickness of 0.2 ~ 0.3mm, the finished proct is about 3.0mm
4. 1617 is a line type of UL758 electronic wires. For electronic wires, the standard does not define the OD of wire rod, but only limits the skin thickness. Generally, it limits the minimum average thickness and the minimum skin thickness at any point (in addition to the line type regulations, it also depends on whether there are additional restrictions (facing page))
the following is the linetype information:
style 1617 insulated wire.
rating 105 DEG C, 600 VAC, horizontal flame.
insulation labeled or combining with the manufacturer; S AWM Procere.
covering PVC: from 5 to 40 mils.
standard appliance wiring material UL 758.
marking general.
use internal wiring of electronic equipment.
hope to help you.
the following is the linetype information:
style 1617 insulated wire.
rating 105 DEG C, 600 VAC, horizontal flame.
insulation labeled or combining with the manufacturer; S AWM Procere.
covering PVC: from 5 to 40 mils.
standard appliance wiring material UL 758.
marking general.
use internal wiring of electronic equipment.
hope to help you.
5. Bolingkewei - for you, od260 / od280 are less than 1.2, genomic DNA pollution; Degradation may also have, the best you run PCR look, there should be smear - pollution
6. Nmoles per od 4.3 with 4.3 nmol primers per od
u μ, Um is micromolar,
TM is annealing temperature, which means that the best annealing temperature is 71.76 when buffer is 1mna +.
but this is the reference value, so it is recommended to make gradient on PCR instrument
u μ, Um is micromolar,
TM is annealing temperature, which means that the best annealing temperature is 71.76 when buffer is 1mna +.
but this is the reference value, so it is recommended to make gradient on PCR instrument
7. I can only give you the formula, look at the resistivity meter, what metal is it made of, you can calculate it,
8. The saying "1od = 0.05ug/ul" is not rigorous. According to my understanding, this sentence means: in the absorption cell with the optical path of 1cm, when the OD value of double stranded DNA is 1, the concentration of DNA solution is 0.05 G/