1. I'm not very clear about the EFC Miner you mentioned. Referring to the previous client login problem, it's recommended to change the browser to login first. Sometimes browser compatibility will affect login
2. Yes, I bought a system with SSR function on the basis of the original version when I first came out. Now many of them can brush after so long
3. It's also the first time to buy this fixun K2P router. The machine is really good. At first glance, it's a big brand proct. Originally, I thought it was troublesome to set up a new router. As soon as I replaced it, it was finished in a few minutes, and the notebook can be connected to the Internet. It's really a big brain hole. The manual is very detailed and easy to understand. It's easy to operate step by step. The app of fixun K2P is very convenient, You can see how many connected devices are online, which devices can be seen clearly, and you can also limit the speed and control the time of a single device.
4. Hello! Not enough. The maximum output current of 50KVA transformer is 50 * 1.44 = 72A. If there are not too many electrical appliances in each household, assume that each household only uses 1000W of electricity (the current is 4.5a, 1000W is the bottom line), that is 72 / 4.5 = 16 households. If not all electrical appliances are turned on, we assume that only 50 households use electricity every day, and the maximum is 32 households. Do you want to consider whether it is in the evening or in the summer? So 50KVA transformer is not enough. If 100 families use electricity normally, and the transformer is enough, they need at least 200KVA
I hope it can help you
I hope it can help you
5. According to the power consumption, only the average value can be calculated,
if the load is constant, the average value can be used,
but the actual situation is mostly variable, so it should be calculated according to the actual installed load.
if the load is constant, the average value can be used,
but the actual situation is mostly variable, so it should be calculated according to the actual installed load.
6. According to the power factor of 0.9
the apparent power is 10000 / 0.9 = 11111kva
the closest national standard transformer capacity is 12500kVA
the apparent power is 10000 / 0.9 = 11111kva
the closest national standard transformer capacity is 12500kVA
7. There is no need to overhaul, and a high-voltage test is needed in 2-3 years. 1-2 years to clean the st, check the cooling fan and tighten the screws
if there is a problem in the high-voltage test, repair it.
if there is a problem in the high-voltage test, repair it.
8. First, the U.S. Treasury issues treasury bonds, and then gives them to the Federal Reserve as collateral, and then the Federal Reserve can issue money
9. Unknown_Error
10. Qt-100 detector: when the green light is on, the power supply light is always on, the yellow light is the fault light, the red light is the concentration alarm light, and when there is concentration, it will flash, and when there is an alarm sound, there is a concentration alarm