Peinahai service center to the 30th floor of Tianjin Internation
1. External influence: all kinds of influences from the outside of the clock, depending on the working environment of the clock
2. Fast slow needle: fast slow needle is an economic structure that is convenient for timing, but both theory and practice have proved that it will affect the isochronicity of the system, and may also proce potential difference. These timing errors are relatively random and cannot be compensated or offset
3. Friction: friction usually has positive and negative effects, such as friction wheel, friction between automatic watch spring and strip box, screw self-locking, etc; On the other hand, friction will lead to the rection of transmission efficiency and the friction loss of parts, thus affecting the timing
4. Escapement: the impact of escapement is mainly the impact on the cycloidal hairspring system in the process of energy transfer. The cycloidal hairspring system can maintain a fixed vibration frequency only in the case of free vibration. Obviously, the energy transfer process of escapement will affect the vibration frequency. The theory shows that when the transmission process is close to the balance point of the balance wheel, the influence will be reced
5. Temperature influence: the influence of temperature is mainly manifested in two aspects: first, the temperature change will change the working length of the hairspring, and change the inertia of the balance wheel, which can directly affect the timing accuracy; Secondly, the temperature change will affect the viscosity of the lubricating oil, affect the transmission efficiency, and thus affect the timing
6. Magnetic field: the hairspring which is most affected by the magnetic field can change its elastic molus, and also deform the hairspring under the action of the magnetic field, resulting in additional stress. In severe cases, the magnetic field can cause adhesion of the hairspring and seriously affect the travel time
7. Balance of hairspring: the center of gravity of the general swing frame hairspring changes with the change of the swing angle of the balance wheel. Under the action of gravity, it will proce position error
8. Balance of the balance wheel: the balance of the balance wheel elements directly affects the bit difference, and the static balance of the balance wheel elements is a basic requirement.
1) insufficient power storage: you need to check whether the power is sufficient first. If the amount of movement of the mechanical watch on the chain is very small, it may also cause insufficient power storage. You can supplement the power by manually on the chain, and then observe whether the phenomenon of speed continues
2) insufficient power: if the quartz watch suddenly finds that it is slow, it may be caused by insufficient battery energy, you can send the watch to a special maintenance point to check the power
3) have been hit or hit: the watch is very tight. If it is hit or hit, it may cause internal parts loose and damage, and it may also cause travel time problems. This is to be dealt with in time
4) maintenance required: the lack of oil in the movement or the wear and aging of internal parts may cause travel time problems, which need to be maintained and sent to the designated repair point for maintenance
5) in addition to the above common cases, the watch is magnetized e to the influence of some ambient temperature: if the hairspring of the watch is magnetized, the watch's travel time will be inaccurate.
whether it is all steel or precious metal case, there is always the problem of wear. A lot of people will be attracted by the words stainless steel, never wear and tear. But in fact, even the case made of the best steel will be worn. Even the buckle will wear out when it comes into contact with the desktop naturally every day. For example, a long time to knock the keyboard, will lead to the button on the ugly pattern. For this reason, proper attention should be paid not to let the case and watch chain participate in unnecessary wear, which is also needed to make our quartz watch "look very new"
when adjusting a watch, you should avoid screwing the crown too fast. The small components in a precise mechanical watch are quite fragile compared with the strength of human hands. Therefore, if you are not proficient in the initial adjustment or adjustment, it is very necessary to read the brand manual carefully first. When encountering unexpected resistance, don't use too much force. It may be that the operation is wrong. Slow motion can avoid some unnecessary damage.
1. Insufficient kinetic energy: insufficient top chord and kinetic energy. In particular, the automatic mechanical watch requires a large amount of arm activity, and the efficiency of chain up is very low. If you usually exercise a small amount, you can wind it manually, which can ensure enough kinetic energy
2. Gear failure: gear train failure such as eccentric wheel and center wheel failure will cause watch to stop stealthily. These cases are often not easy to find, need to be disassembled, careful inspection and testing in order to find out the problem and solve the problem
3. Lack of maintenance: the mechanical watch should be maintained every 2-3 years or so. If it is not maintained for a long time, a lot of sludge will be proced inside. The friction between gears will increase, leading to the occurrence of sliding teeth
there will be an after-sales telephone number on your warranty sheet. Call the after-sales telephone number to inquire about the after-sales address.
when wearing a watch, the sweat on the hand is corrosive to the watch case. Because the all steel case is made of nickel chromium alloy, it has better corrosion resistance, and the half steel case is made of copper. It is easy to corrode e to long-term contact with sweat. You should often wipe away the sweat with a soft cloth or pad a plastic watch holder to prevent it from being eroded by sweat. Don't put the watch on the radio or TV to avoid magnetization. Do not put the watch in the wardrobe with camphor pills to avoid the deterioration of the watch oil. Do not open the back cover of the watch at will to avoid st entering the movement and affecting the normal operation of the watch. If the watch is not worn for a long time, it should be wound regularly once a month to prevent the parts from being stationary for a long time, so as to ensure the operation performance of the watch machine
if the water in the watch is very serious, the maintenance of the watch is not only to deal with the water in the watch, but also to open the cover to maintain the parts in the watch. Refill the parts in the watch. Because the water is made of iron oxide, if a lot of water is put into the watch, the parts in the watch will be oxidized
for the protection of waterproof watch, when it is not worn normally, try not to let the watch get damp to avoid leather deformation; The accuracy of the watch will also be affected if it is placed near magnetic objects. In addition, even the waterproof watch should also avoid soaking the watch, and as long as the watch has been soaked (except for the diving watch), it is best to enter the site for inspection, so as to avoid serious damage to the internal movement parts e to time delay. In fact, the waterproof degree of waterproof meter will change with the hardening of waterproof ring, so timely replacement of waterproof ring is necessary. Hot and humid weather, it is easy to make the watch internal oil condensation, resulting in stop and go, slow or completely stop phenomenon, and will cause the hardening of the waterproof ring, rece the waterproof function. It is particularly noteworthy that seawater contains salt, which is corrosive to metal components. Therefore, after outdoor activities, the watch shell should also be washed with fresh water to avoid corrosion
[service address: room 3003, 30 / F, Tianjin International Financial Center building, 136 Chifeng Road, Heping District, Tianjin]
the after-sales point of Tianjin Tiansuo watch is at [136 Chifeng Road, Heping District, Tianjin - 30th floor, Tianjin international financial center]
I. The main reasons for the loss of Tiansuo watch are as follows:
-
wear of splint
-
the wear of tail hook
-
the pulling screw is loose
-
the handle is deformed and damaged
-
2. How to deal with the loss of Tisuo watch handle:
-
if the handle of Tisuo watch falls off ring wearing, we should keep it properly and send it to a professional watch repair shop in time. Don't insert it into the watch by yourself. Doing so may make the reclining wheel separate from the clutch rod, increase wear and tear, and increase trouble for future maintenance
-
and when we pull out the watch handle to pick the time, we must remember to pull it gently, or even the brand-new Tisuo watch may pull out the watch handle in the process of pulling out the watch handle
- < UL >
peinahai Service Center Address (take Fujian Province as an example):
1. Fuzhou maintenance service center:
(1) service telephone: service telephone: 400-901-0519
(2) business hours: 9:00-19:00 (on holidays)
(3) repair address: room 03, 15 / F, henglicheng office building, 128-1 Wusi Road, Gulou District, Fuzhou (next to Minjiang Hotel)
2. Xiamen Service Center:
(1) service telephone: 400-960-4985
(2) business hours: 9:00-19:00 (on holidays)
(3) repair address: unit C, 24th floor, Xiamen International Bank building, 8 Lujiang Road, Siming District, Xiamen (near Zhongshan Road)
it is recommended to call the service center hotline 4009604985 for consultation. Go to the service center by yourself and send the watch to the service outlets for pre inspection and maintenance
extended information
Fuzhou maintenance service center:
(1) subway route: take subway line 1 to Doumen station (exit a), walk 80 meters to No. 69 of Doumen bus station, get off at Minjiang Hotel station, walk 10 meters to room 03, 15th floor, henglicheng office building
(2) bus route: take bus No.2; Route 5; Route 55; 69 road; Route 72; 76 road; 129 road; 328 road; Get off at Minjiang Hotel Station on K3 road and enter room 03, 15th floor, henglicheng office building on the left side of Minjiang hotel
Xiamen maintenance service center:
(1) metro route: Metro Line 1 goes out of Zhenhai Road Station Exit 1, walk 200 meters to the southwest, then walk 500 meters to the right along Lujiang road to reach unit C, 24th floor, international bank building
(2) bus route: take 2, 3, L1, 8, 10, 11, 19b, 19A, 25, 29, 31, 32, 97, 107, 116, 118, 127, 139, 310, 853, 941, 950 Haibin building station